How we test.

Precise, repeatable testing for research-use peptides. Every test runs to one written method, so results from different batches and months can be compared directly.

Standard turnaround: 24–72 hours

Endotoxin test

Endotoxin level in EU/mL

LAL, kinetic chromogenic

HPLC-MS test

Purity, identity and quantity (mg)

HPLC with ESI mass spec

Endotoxin test

Endotoxin level in EU/mL

LAL, kinetic chromogenic

Bacterial endotoxin

Measures endotoxin contamination, the residue bacteria leave behind, and reports the level in EU/mL.

On the certificate

  • Endotoxin level (EU/mL)
  • Pass/fail against specification

HPLC-MS test

Purity, identity and quantity (mg)

HPLC-MS

Purity

How much of the sample is the compound you expect, as an area-percent purity with the HPLC graph attached.

On the certificate

  • Purity (%)
  • Retention time
  • HPLC graph

HPLC-MS, ESI positive mode

Identity

Confirms the molecule is what the label says by comparing the observed mass with the theoretical molecular weight.

On the certificate

  • Observed vs. theoretical mass
  • Pass/fail against tolerance
  • Mass spec graph

HPLC-MS against a reference standard

Quantity

The actual milligrams of compound in each vial, so the stated amount can be checked rather than assumed.

On the certificate

  • mg per vial
  • Percent of label claim

Reporting

From sample to verified certificate.

  1. 1

    Sample logged

    Each sample is logged against its batch lot number when it reaches the lab.

  2. 2

    Tested to method

    Endotoxin by kinetic chromogenic LAL; purity, identity and quantity by HPLC-MS.

  3. 3

    Checked and approved

    Our analyst records the results, attaches the HPLC and mass spec graphs, checks everything and approves the batch.

  4. 4

    Certificate published

    The COA is issued with its own ID and QR code, and its public record goes live on our Verify page.

On every certificate

The batch lot number and test date, the client it was issued to, and the method, specification and measured result for each test, with the HPLC and mass spec graphs attached and a QR code linking to its public record.

Revoked means revoked

If a certificate is ever withdrawn, its public record says so immediately, with the date and reason, and the PDF is marked revoked.